Mitsubishi FX2-24MR PLC SUPERIOR QUALITY PRODUCT SHIPPING WORLDWIDE

Input: 12 digital input S/S
Output:
12 Relay Output
Power supply : 
85 – 264V AC, 50/60 Hz
FX-24MR-ES/UL Internal relays: 1536 aux relay
Data register: 1000 MW
FX-24MR-ES/UL Timers: 256 timer relay
States: 1000 bit
Counters: 256 standart
FX-24MR-ES/UL High speed counters: Max 6 32 bits up/down counting ,
Max frequency 20 Khz/ 2 khz
Operation processing time: Basic instruction :0,48 microsec.
-Applied instruction:10-100 microsec.
Max. allowable momentary power failure period: Fuse (size) rateing:
(Æ 5 ´ 20 mm (0.2 ´ 0.79 inches))
FX-16M, 24M, 32M/E =3.15A,(type 50CT-032H)
FX-48M/E, 64M, 80M, 128M,FX2C-64M, 96M, 128M, 160M = 5A
(type 50CT-050H)
In-rush current: FX-PPM/E: 100V AC Max. 50A < 5msec,
200V AC Max. 60A < 5msec FX-128M/E:100V AC Max. 50A < 7msec,
200V AC Max. 70A < 7mse FX2C-PPM: 100V AC Max. 40A < 5msec,
200V AC Max. 60A < 5msec
FX-24MR-ES/UL Power consumption: FX-16M, 24MR-UA1 = 30VA
FX-24M = 35VA
FX-32M/E = 40VA
FX-48M/E, 64MR-UA1 = 50VA
FX-64M = 60VA
FX-80M = 70VA
FX-128M = 100VA
FX2C-64M, 96M = 80VA
FX2C-128M, 160M = 120VA
Class 3 ground
FX-24MR-ES/UL Earthing/Grounding
Use a cable at least 2mm2 (AWG14) to ground equipment. Ground resistance must
be less than 100W (class 3). Note that the ground cable must not be connected to the
same ground as the power circuits. Grounding is recommended but if a proper ground
cannot be provided the PC will still operate correctly without being grounded.
Signal Ground (SG); Each SG terminals should be linked with 2mm2 (AWG14) cable.
The linked cable should then be grounded to earth at only one point.
If the system being installed uses the service supply from both the PC and a
powered extension block , then the 0V terminals should be linked.

· DO NOT however, link the 24V terminals.
· NEVER connect an external power supply to the PC’s 24V terminal.
· External DC supplies should not compromise the SELV aspects of the FX/FX2C products.
Order by 2PM to get delivered next working day! We use 24 hours service with carriers in most cases so that you can get your order delivered on time.

There is £4.99 charge for delivery under £50 Orders. Additional charges will be imposed by our couriers for delivery to remote area, a surcharge may be levied to cover carriage to these areas.

Reviews

There are no reviews yet.

Be the first to review “Mitsubishi Fx2-24Mr Plc Superior Quality Product”

Your email address will not be published. Required fields are marked

You have to be logged in to be able to add photos to your review.

Mitsubishi Fx2-24Mr Plc Superior Quality Product

 8,627.50

Estimated delivery:5 days

Mitsubishi FX2-24MR PLC SUPERIOR QUALITY PRODUCT SHIPPING WORLDWIDE

Input: 12 digital input S/S
Output:
12 Relay Output
Power supply : 
85 – 264V AC, 50/60 Hz
FX-24MR-ES/UL Internal relays: 1536 aux relay
Data register: 1000 MW
FX-24MR-ES/UL Timers: 256 timer relay
States: 1000 bit
Counters: 256 standart
FX-24MR-ES/UL High speed counters: Max 6 32 bits up/down counting ,
Max frequency 20 Khz/ 2 khz
Operation processing time: Basic instruction :0,48 microsec.
-Applied instruction:10-100 microsec.
Max. allowable momentary power failure period: Fuse (size) rateing:
(Æ 5 ´ 20 mm (0.2 ´ 0.79 inches))
FX-16M, 24M, 32M/E =3.15A,(type 50CT-032H)
FX-48M/E, 64M, 80M, 128M,FX2C-64M, 96M, 128M, 160M = 5A
(type 50CT-050H)
In-rush current: FX-PPM/E: 100V AC Max. 50A < 5msec,
200V AC Max. 60A < 5msec FX-128M/E:100V AC Max. 50A < 7msec,
200V AC Max. 70A < 7mse FX2C-PPM: 100V AC Max. 40A < 5msec,
200V AC Max. 60A < 5msec
FX-24MR-ES/UL Power consumption: FX-16M, 24MR-UA1 = 30VA
FX-24M = 35VA
FX-32M/E = 40VA
FX-48M/E, 64MR-UA1 = 50VA
FX-64M = 60VA
FX-80M = 70VA
FX-128M = 100VA
FX2C-64M, 96M = 80VA
FX2C-128M, 160M = 120VA
Class 3 ground
FX-24MR-ES/UL Earthing/Grounding
Use a cable at least 2mm2 (AWG14) to ground equipment. Ground resistance must
be less than 100W (class 3). Note that the ground cable must not be connected to the
same ground as the power circuits. Grounding is recommended but if a proper ground
cannot be provided the PC will still operate correctly without being grounded.
Signal Ground (SG); Each SG terminals should be linked with 2mm2 (AWG14) cable.
The linked cable should then be grounded to earth at only one point.
If the system being installed uses the service supply from both the PC and a
powered extension block , then the 0V terminals should be linked.

· DO NOT however, link the 24V terminals.
· NEVER connect an external power supply to the PC’s 24V terminal.
· External DC supplies should not compromise the SELV aspects of the FX/FX2C products.
Order by 2PM to get delivered next working day! We use 24 hours service with carriers in most cases so that you can get your order delivered on time.

There is £4.99 charge for delivery under £50 Orders. Additional charges will be imposed by our couriers for delivery to remote area, a surcharge may be levied to cover carriage to these areas.

Reviews

There are no reviews yet.

Be the first to review “Mitsubishi Fx2-24Mr Plc Superior Quality Product”

Your email address will not be published. Required fields are marked

You have to be logged in to be able to add photos to your review.

Buy more save more!

Buy from 2 to 4 items and get 10% OFF
on each product
Buy from 5 to 8 items and get 15% OFF
on each product

In stock

or
Categories: , , Tag:
Got Questions? Feel free to Get in touch
Guaranteed safe checkout Pay safely with Visa Pay safely with Master Card Pay safely with PayPal Pay safely with American Express Pay safely with Bitcoin Pay safely with Maestro
Your Payment is 100% Secure